P3 Joist – PJI 40 – Allowable uniform loads [PLF] Roof – Table 12
9/12″ 11 7/8″ 14″ 16″
Clear Joist Span [ft] Unfactored*
Live L/360
Unfactored*
Live L/240
Total L/180  Factored Total Load  Unfactored*
Live L/360
 Unfactored*
Live L/240
Total L/180  Factored Total Load  Unfactored*
Live L/360
 Unfactored*
Live L/240
Total L/180  Factored Total Load  Unfactored*
Live L/360
 Unfactored*
Live L/240
Total L/180 Factored Total Load
 8  344  419 419  419
 9 299  306  374 374  374
 10 227  276  337 337  337
 11  176 252 287  308  308  308
12  139  209  231  228  282  282  282
 13  112  168  208 184  261  260  261  261
14  91  137  180 151 226  233  214 243  243
 15  75  113  150  157 125 187  203 178  227  227
16  62  94  125  138 104  157  179  149  213  199  213
17  52  79  105  122 88  132  159  126 189  191  168  201
18  45  67  90  109 75  112  142  107 161  171  144  190
 19 38  57  77 98 64  96  127  92 139  153  124  178
 20 33  49 66  89 55  83 111  115  80 120  138  107 161
21 28  43  57  80 48  72 97  104  69 104  126  94  141  146
22 25  37  50  73 42  63  85  95 61 91  115  82  123  133
 23 22  33  44  67 37  56  74  87 54 81  105  72  109  122
 24 19  29  39  62 33  49  66  80  47 71  96  64  96  112
 25 17  26 34  57 29  44  58  74  42 63  89  57 86  103
 26 15 23  31  52 26  39 52  68  37 56  82  51  76  95
 27 13 20  27  49 23  35  47  63  34 51  76  46  69  88
 28 21  31  42  59  3 45  71  41  62  82
 29 19  28  38  55  27 41  66  37  56 74  77
 30 17  25  34  51  25 37  62  33  50 67  72
 31 15  23  31  48  22 34  58  30  46 61  67
 32 14  21  28 45  20 31  54  28 42  56  63
 33 13  19  26  42 18 28  51  25  38 51  59
 34 11  17  23 40  17 26  48  23  35  47 56

*Unfactored loads based on deflection.

 

P3 Joist – PJI 60 – Allowable uniform loads [PLF] Roof – Table 13
9/12″ 11 7/8″ 14″ 16″
Clear Joist Span [ft] Unfactored*
Live L/360
Unfactored*
Live L/240
Total L/180  Factored Total Load  Unfactored*
Live L/360
 Unfactored*
Live L/240
Total L/180  Factored Total Load  Unfactored*
Live L/360
 Unfactored*
Live L/240
Total L/180  Factored Total Load  Unfactored*
Live L/360
 Unfactored*
Live L/240
Total L/180 Factored Total Load
 8  344 419  419  419
 9  306 374  374  374
 10  263 376 337  337  337
 11  205 252 308  308  308
 12 163 231  265 282 282  282
 13 131  197  213 215 261  261  261
 14 107 161  198 177 243  243  243
 15 88  133  177  185 146 220  227  209  227  227
 16 74 111  148  174 123  184  213  176  213  213
 17 62 93  125  164 104  156  201 149  201  199  201
 18 53 79  106  151 88  133  177  190 128  190  171  190
 19 45 68  91  136 76  114  152  176 110 165 180  147  180
 20 39 59  78  123 66  99 132  159 95  143  171  124  171
 21 34 51  68 111 57  86 115  144 83  125  163  112  163
 22 29 44 59  101 50  75 100  132 73  109 146  156  98 148  156
 23 26 39  52  93 44  66 88  120 64  96  129  145  87  130  149
 24 23 34  46  85 39  59 78  111 57  85  114  133  77 115  143
 25 20 31  41 79 35  52 70  102 50  76  101  123  68 103  137
 26 18 27 36  73 31  46 62  94 45  68  91  114  61 92 123  132
 27 16 24  33  67 28  42 56  88 40  61  81  105  55 82 110  122
 28 25 37 50  81 36  55  73  98  49 74 99  114
 29 22  34 45  76 33  49  66  91  45 67 90  106
 30 20  30 41  71 30  45  60  85  40 61 81  99
 31 18  28 37  66 27  41  54  80  37 55 74  93
 32  17  25 34  62  25  37  50  75  33 50 67  87
 33  15  23 31  59  22  34  45  71  31 46 62  82
 34  14  21 28  55  20 31  41  66  28 42 56  77

*Unfactored loads based on deflection.

 

P3 Floor Joist – PJI 80 – Allowable Uniform Loads [PLF] – Table 14
11 7/8″ 14″ 16″
Clear Joist Span [ft]  Unfactored*
Live L/360
 Unfactored*
LiveL/240
Total L/180  Factored Total Load  Unfactored*
Live L/360
 Unfactored*
Live L/240
Total L/180  Factored Total Load Unfactored*
Live L/360
 Unfactored*
Live L/240
Total L/180  Factored Total Load
 8  420 459  487
 9  375 410  434
 10 338 370  392
 11 308 337  357
 12  283 310  328
 13  262 286  303
 14 231  243 266  282
15 193  227 249  264
16  163  213  230 234  247
 17  138  201  196 220  233
 18  118 177  190  168 208  220
 19 102  153  180  145 197 193  209
 20  88  133  171  126 187  168  199
 21  77  116  155  164  111  166 179  147  189
 22  68 102  136  156  97  146 171  130  181
 23 60  90  120  149  86  129 163  115  173  173
 24  53  79  106  143  76  115  153 156  102 153  166
 25 47  71  94  137  68  102  136 150  91 137  159
26  42  63  84  132  61  91  122  145  82 123  153
 27  38 57  76  124  55  82  110  139  73 110  147  148
 28 34  51  68  115  49  74  99  134  66 99  133  142
 29 31  46  62 108  44  67  89  130  60 90  120  137
 30 28  42  56  101  40  61  81  121  54 82  109  133
 31  25  38  51  94  37 55  74  114  49 74  99  129
 32  23 34  46  88 33  50 67  107  45 68  91  124
 33  21  32 42  83  30 46  61 100  41 62  83 116
 34  19  29  39  78  28  42  56  94  38 57 76  110
*Unfactored load based on deflection.

 

P3 Joist – PJI 80 with Web Stiffeners – Allowable uniform loads [PLF] Roof – Table 15

 

9/12″ 11 7/8″ 14″ 16″
Clear Joist Span [ft] Unfactored*
Live L/360
Unfactored*
Live L/240
Total L/180  Factored Total Load  Unfactored*
Live L/360
 Unfactored*
Live L/240
Total L/180  Factored Total Load  Unfactored*
Live L/360
 Unfactored*
Live L/240
Total L/180  Factored Total Load  Unfactored*
Live L/360
 Unfactored*
Live L/240
Total L/180 Factored Total Load
 12  405  405  405  405
13  375  375 375  375
 14  348  348  348  348
 15  326  326  326  326
16  306  306  306  306
 17  288  288  288  288
 18  272  272  272  272
 19  244  258  258  258  258
 20  213  245  245  245  245
 21 187  234  232  234  234  234
 22 165  223 205  223  223  223
 23  146  214 182  214  214  214
 24  130  195  205 162  205 197  205  205
 25  116 175  197 145  197  177  197  197
 26  104 157  189 130  189  159  189  189
 27  94 141  182 117  176  182  143  182  172  182
 28  85 127  170  176 106  159  176  130  176 155  176
 29  77 115  154  170 96  144  170  118  170 141  170
 30  70 105 140  160 87  131  164  107 161  164  129  164
 31  63 95 127  150 80  120  159  98 147  159  117  159
 32  58 87 116  140 73  109  146  154  89 134  154  107  154
 33  53 80  107  132 67  100  134  146  82 123  149  98 148  149
 34  49 73  98  124 61  92  123  138  75  113  145  91 136  145
 35 45 67  90  117 56  85  113  130  69  104 139  141  83 125  141
 36  41 62  83  111 52  78  104  123  64  96 128  135  77 116  137
 37  38 57  77  105 48  72  97  116  59 89  119  128  71 107  133
 38  35 53  71  100 44  67  89  110 55  82  110  121  66 99  130
39  33 49  66  95 41  62  83  105  51  76  102  115  61 92 123  125
40  30 46  61  90 38  58  77  100  47  71  95  109  57 86 114  119
 41  28 43  57  86 36  54  72  95  44  66  88 104  53 80  107  113
42 26 40  53  82 33  50  67  90  41 62  82  99  49 74  99  108
43 24 38  49  78 31  47  62  86  38  58 77  95  46 70  93  103
44 23 35  46  74 29  44  58  82  36  54  72  90  43 65  87  98

*Unfactored loads based on deflection.

NOTES

  1. Clear span is the distance between the face of the supports.
  2. The load values are for standard term load duration and dry service conditions only. The dead load must not exceed the live load.
  3. The load values above represent the worst case of simple span or multiple span single member applications.
  4. Design of continuous spans is based on the longest span. The shortest span must not be less than 50% of the longest span.
  5. Provide continuous lateral support for top flange. Provide lateral support at points of bearing to prevent twisting of joist.
  6. The unfactored load columns are based on deflection only. The factored load column is based on strength only.
    Unfactored live load (either L/360 or L/240), unfactored total load, and factored load must be checked.
    Where the unfactored load column is blank, the factored load column governs.
  7. Provide 1-3/4” bearing at end supports and 3-1/2” bearing at interior support minimum.
  8. Web stiffeners are required at each support.
  9. The loads have been calculated in accordance with CSA O86S1-05.
  10. Use the horizontal span from the building plans to size the joists.
    For slopes greater than 1 in 12, multiply the tabulated loads by the appropriate factor listed below.
    Provide a roof slope of at least 1/4 in 12 for drainage.